Samsung air conditioner fault code books and solution

by:DEFUS     2020-06-16
Samsung air conditioner, everybody has heard of, maybe some friends are using it at home. Air conditioning in use after a period of time, more or less will appear some problems. And air conditioning in the event of a problem will display the code Numbers or letters, then, what is the meaning of this code? Here is to introduce the samsung air conditioning fault code books and solution, have a friend needs to understand might as well have a look. A, household samsung air conditioning fault code 1, E1: indoor thermal bag short circuit solution: indoor thermal bag open circuit PCB components of open/short circuit detection, replace the heat pack 2, E2, flaws, door sensors, door motor cable poor contact solution: bad replacement door motor assembly, replace the sensor, replace cables, eliminate interference structure 3, E4: grille motor defect solution: limit switch defect, cable poor contact assembly change bad grille motor change limit switch replacement cable to eliminate interference 4 structure, E5: indoor pipe bulb open, indoor temperature package short circuit PCB components open/short circuit test solution: replace the tube bulb. 5、E6:化霜管温包开路解决方法:化霜管温包短路PCB部件的开路/短路检测,更换化霜管温包6、E7:电加热器温度传感器开路解决方法:电加热器温度传感器短路PCB检测、更换温度传感器7、E0:电加热器超高温,室内电机堵转解决方法:室内电机损坏检测高温传感器、消除室内电机堵转的因素、更换室内电机二、中央式三星空调故障代码E121:内机温控开路/短路E122:内机蒸发器入口温控开路/短路E123:内机蒸发器出口温控开路/短路E124:内机通讯故障E128:内机入口温控脱落E129:内机出口温控脱落E130:内机出入口温控同时脱落E131:辅助电加热温控1故障E132:辅助电加热温控2故障E133:辅助电加热温控3故障E134:风口温控故障E135:风扇温控故障E151:内机电子膨胀阀开2次三、与内机相关故障E152:内机电子膨胀阀关2次E153:内机浮子开关2次感应E154:内机风扇故障E162:EEPROM故障E163:OPTION设置故障E164:与特别消费税金相关故障E165:电加热排除温度保护E166:与电加热相关的无风故障E201:设定台数故障四、与外机通讯故障E202:内机与外机通讯故障E203:外主机与辅助机通信故障E221:外机温度温控开路或短路五、与外机传感器有关E226:外机温度温控脱落E231:冷凝器主温控故障E236:冷凝器辅助温控故障E241:冷凝器中部温控故障E246:冷凝器出口1温控故障E251:数字排气温度温控故障E256:定速压缩机1温控故障E257:定速压缩机2温控故障E261:数字排气温控故障E262:定速压缩机1温控故障E263:定速压缩机2温控故障E265:SUMP温控故障( Lord) E266: SUMP temperature control failure ( Secondary 1) E267: SUMP temperature control failure ( Auxiliary 2) Six, related to the machine sensor E269: suction temperature control failure E271: digital compressor fault E276 SUMP temperature control: constant speed compressor fault E277 1 SUMP temperature control: constant speed compressor 2 SUMP temperature control fault E291: high pressure sensor ( Before starting the compressor) E296: low pressure sensor ( Before starting the compressor) E301: high pressure sensor fault E306: low pressure sensor fault E307: balance sensor fault E308: suction sensor fault E401: freezing machine perception 1 fault E402: freezing machine perception outside 2 fault E403: freezing machine perception outside 3 fault compressor protection E404: outside the machine overload protection control fault E405 1: the machine load 2 protection fault E406: outside the machine load 3 protection fault E407: high pressure sensor 1 protection compressor stop E408: high pressure sensor 2 protection compressor stop E409: high pressure sensor 3 protection compressor stop E410: low pressure sensor 1 protection compressor stop E411: low pressure sensor 2 protection compressor stop E412: low pressure sensor 3 protection compressor stop E413: outdoor SUMP, DOWN - 1 protection E414: outdoor SUMP, DOWN - 2 protection E415: outdoor SUMP, DOWN - 3 protection E416: outdoor air 1 protection E417: outdoor air 2 protection E418: outdoor air 3 protection E419:1 self-diagnosis open control E420 outdoor electronic valve: outdoor electronic valve open control E421 self-diagnosis: 2 3 self-diagnosis open control E422 outdoor electronic valve: 1 since the diagnosis of closed control E423 outdoor electronic valve: outdoor electronic valve since the diagnosis of closed control E424 2:3 since the diagnosis of closed control E425 outdoor electronic valve: outdoor reverse fault E426 perception 1: outdoor reverse 2 fault E427 perception: outdoor backward perception 3 fault E428: outdoor fault E429 compression ratio 1: outdoor compression ratio 2 fault E430: outdoor compression ratio 3 fault E434: balancing valve open fault E437: balance valve clearance fault E440: heating when outdoor temperature is above 30 degrees: toE441: outdoor temperature in - when refrigeration 5 below: tuE442: outdoor temperature 15 degrees above charge into the model to ban E443: refrigeration starts under low pressure 1 KGF E551: defrost E553: balance running E554: loading failure machine without condensation E555: recycle oil running E601: wired remote controller communicates with the inner E605: seven days schedule and wired remote control, communication CAUR E701: FLOAT a E602: the main controller and from drive-by-wire communication failures E702: indoor electronic expansion valve shut a E703: indoor electronic expansion valve to open a E552: low exhaust fault ok, above is samsung air conditioning fault code books and solution related introduction, hope to be of help!
Custom message
Contact